Get a copy of the AISC Search Utility for Structural Shapes.
The member may be an S12X25 manufactured by Phoenix Iron Company.
Library: HISTORIC
Type: S
ID = 346
Designation = S 12x25
A = 7.35
D = 12.00
TW = 0.240
BF = 5.000
TF = 0.464
T = 9.882
K = 1.059
W = 25.0
BF_2TF = 5.39
H_TW = 41.2
FY3P = 38
X1 = 2546
X2 = 3769
IX = 182.7
ZX = 34.0
SX = 30.5
RX = 4.99
IY = 7.6
ZY = 5.20
SY = 3.0
RY = 1.02
J = 0.51
CW = 253
a = 35.8
WNO = 14.4
SW = 8.35
QF = 6.36
QW = 17.0
FStr = PH 1915,PH 1923,PH 1929,
From: Mark@Crownjade.com [mailto:mark@crownjade.com]
Sent: Friday, December 03, 2010 12:11 PM
To: seaint@seaint.org
Subject: Beam properties
I have an existing building with RTU’s being added and need to analyze the beams. The simplest of course is a table of properties. The beam dimensions don’t fit W, M, S, or HP per AISC 9th. It is an I-shape with a slightly tapered flange (I didn’t get that difference in thickness dimension), d=12-3/16”, bf=5”, tf=3/8” (by subtraction) and tw=1/4”. The beams are fairly light. Does anybody know where to find the properties for these? They are in a 50 to 80 year old Denver, CO building.
Thank You, Mark Benjamin
Crown Jade Design and Engineering, Inc.
(970) 472 2394 www.crownjade.com
Engineered For the Way You Build...
...Designed For the Way You Live
Licensed in AZ, CO, CT, ID, KY, MN, NM, PA, WY... and your state!
P Please do not print this e-mail unless it is completely necessary! Think about the environment.
Confidentiality Statement: This message is solely for the use of the intended recipient. This message is confidential, and may contain legally-privileged information. If you are not the intended recipient, be aware that any review, disclosure, copying, distribution, reliance upon or use of the contents of this message is strictly prohibited. If you have received this message in error, please destroy it and notify me immediately. Thank you.
No comments:
Post a Comment